The main hardware parts of the system are as follows:
• Electronic Load Indicator (ELI)
The ELI is an electronic sensor device that continuously measures and
monitors tensions. It is installed into the hanging during anchor installation
in the support phase after a blast.
The ELI detects any change in tension and reports to the EMCA.
Functionality summary:
• Electronic Monitoring Cable Anchor (EMCA)
The EMCA is another electronic device that accepts information from the
ELI and relays information to surface for further processing and reporting.
The EMCA forms part of an EMCA wireless mesh network that
automatically forms the network to relay information to surface. The EMCA
also has visible indication in case warnings needs to be issued.
• Closure Monitoring Device (CMD)
This product is a EMCA and ELI together with a Camlock device for re-use
and movability.
Multiple EMCA and ELI pairs are installed every 10 to 20 metres underground or
more frequency if required. Future expansion would include multiple ELI’s to be
connected to one EMCA to expand the area of monitoring using a single EMCA
and thus be more cost effective.
EMCA, ELI and CMD systems are fully battery operated with little maintenance.
Estimated battery life is 2 years following which the batteries are replaced and
recharged. During battery swaps, a backup battery ensures continuous
operation of the system.